EMC/TEST DIVISION EMC / Test Division

Business Description

Providing power port conduction disturbance measurement services and electric field strength measurement services that meets CISPR (International Special Committee on Radio Interference) standards.

Outline of Business

Our company completed EMC testing that meets the legislated EMC standards at the Sado EMC Center in February 2005.
Dimensions: 17.5m xx 22m, Measurement Distance: 3m/10m, Antenna Height: 1m-4m, Turntable Dimensions/Load Diameter: 2m/500kg, Power: 0-260V, 30A, Genuine Testing Facility Electric field measurements and power port conduction disturbance measurements meet the standards of CISPR (International Special Committee on Radio Interference).
Furthermore, all EMC tests necessary for approval/certification of medical device manufacturing and sale can now be performed in-house, as we have facilities such as anechoic chambers to carry out electrostatic discharge tests, electrical fast transient/burst tests, surge tests, and electromagnetic/radio/radiation field tests.

Measurement Facility Overview

Facility Name Sado Open Site
Measurement Method 3m/10m Chamber Method Door Dimensions
200cm x 150cm
Turntable Φ2m 500kg
Power Capacity Single Phase: 0-240V : 30A / Three Phase
Facility Name Sado Anechoic Chamber
Measurement Method 3m/10m Chamber Method Door Dimensions
200cm x 100cm
Turntable Φ2m 500kg
Power Capacity Single Phase: 0-240V : 30A / Three Phase
  • Electric Field Strength Measurement
  • Power Supply Port Electric Interference Measurement
  • Electrostatic Discharge Test
  • Electrical Fast Transient/Burst Test
  • Surge Test
  • Radiation Radio Frequency Field Test

MAP

16-2 Aono, Sado, Niigata Prefecture 952-1326
TEL:+81-259-51-1100 FAX:+81-259-52-5515